Displacement measurement of press machine mold
|
Correct alignment of press dies prevents defective molds.
|
The challenge
Occasionally misplacement of the mold resulted in defective molding. The required accuracy:
- Tolerance: +/-50 micro meter
- Resolution: +/-5 micro meter
|
The solution
Measure the displacement value of the mold and control the condition of forming. This is done with two laser displacement sensor heads and a multi-controller.
|
It is key in this application that the distance between the upper and lower dog (with two sensor heads) is measured this is possible due to the multi-controller.
|
Added value
Damage to the mold can be prevented, which makes production more efficient.
|
|
|